IWDT Example
Source code path: example/hal/wdt/iwdt
Supported Platforms
sf32lb52-lcd_n16r8
Overview
This example demonstrates IWDT usage, including:
IWDT configuration and enabling.
IWDT feeding.
IWDT timeout response.
Example Usage
Hardware Requirements
Before running this example, prepare a development board supported by this example
Compilation and Programming
Switch to the example project directory and run the scons command to execute compilation:
scons --board=sf32lb52-lcd_n16r8 -j32
Run build_sf32lb52-lcd_n16r8_hcpu\uart_download.bat
, select the port as prompted for download:
$ ./uart_download.bat
Uart Download
please input the serial port num:5
For detailed steps on compilation and download, please refer to the relevant introduction in [](/quickstart/get-started.md).
## Expected Results of Example
<!-- Explain example running results, such as which LEDs will light up, which logs will be printed, to help users judge whether the example is running normally, running results can be explained step by step combined with code -->
After the example starts, the serial port outputs as follows:
1. IWDT initialization configuration and enabling successful:
```c
10-28 23:44:00:340 WDT Example:
10-28 23:44:00:342 IWDT init OK. Timeout: 10(s)
10-28 23:44:00:343 WDT_CVR0:0x50000 WDT_CVR1:0x0
Tip
IWDT cannot generate interrupts. Here the working mode (respond mode
) is configured as reset only
, counting only one round, with timeout set to 10 seconds.
Feeding the dog (every 5 seconds):
10-28 23:44:05:270 Watchdog feeding.
10-28 23:44:10:298 Watchdog feeding.
10-28 23:44:15:262 Watchdog feeding.
10-28 23:44:20:291 Watchdog feeding.
10-28 23:44:25:280 Watchdog feeding.
10-28 23:44:31:132 Watchdog feeding.
10-28 23:44:35:300 Watchdog feeding.
10-28 23:44:40:301 Watchdog feeding.
10-28 23:44:45:304 Watchdog feeding.
10-28 23:44:50:320 Watchdog feeding.
After stopping feeding the dog, the first round of counting ends (10s), directly resetting the system:
10-28 23:44:50:320 Watchdog feeding.
10-28 23:45:03:215 SFBL
10-28 23:45:04:945 Serial:c2,Chip:4,Package:3,Rev:2 Reason:00000020
10-28 23:45:04:950 NAND ID 0x7070cd
10-28 23:45:04:957 det bbm table with 1, 1, 2
Exception Diagnosis
Confirm WDT configuration status (enable status, count configuration, working mode) through WDT registers:
After WDT is configured correctly, WDT timeout cannot reset the system:
Need to confirm whetherreboot cause
is correctly configured,HAL_PMU_SetWdt()
can be used to add the corresponding WDT’sreboot cause
:/* Add reboot cause for watchdog. */ HAL_PMU_SetWdt((uint32_t)hwdt.Instance);